Five things you can check yourself
- Measure how high you have to step. The manufacturer Ravak gives the top edge of its Rosa acrylic bath as 610 mm above the floor, and the fitting height of its Gigant Pro cast-marble shower tray as 3 cm. If someone in the family has trouble stepping over a bath rim, these two numbers decide the choice.
- See how the bath stands. On feet or bricked in. Ravak states that an acrylic bath must never be built in rigidly, because it is carried by a reinforced base with adjustable feet. Taking out an old bath that is bricked in means breaking the brickwork.
- Find the access to the trap. For a built-in bath, Ravak requires an opening to be left in one wall for access to the trap and the supply pipes. If your bath has none, the trap can be cleaned or replaced only by removing the finish.
- Find out where the hot water comes from. From the building’s hot water riser or from your own water heater. This matters for a thermostatic mixer, see below.
- Assess the wall and floor finish. A Ravak bath is installed only in a room that is fully finished and tiled. If the tiles still have to be changed, the order is: tiles, then the bath.
A steel bath and an acrylic bath are not the same job
The manufacturer Kaldewei requires a drain with a double-lip seal for a steel enamel bath and shower tray. The bath is loaded before the flexible joint is made, and the load is left until it has dried completely. Mortar or adhesive must not touch the bath’s lower edge directly; a bath sealing tape is advised for this.
For an acrylic bath Ravak leaves a gap of 2–3 mm between the bath and the tiles, which is then filled with silicone. Ravak also advises filling the bath first with cold water and only then with increasingly warmer water.
A thermostatic mixer for children and older people
The manufacturer Grohe gives its thermostatic mixer a safety stop at 38 °C, so the temperature handle stops at this mark. This helps both for a bath and for a shower when a child washes, or a person who reacts slowly to hot water.
Grohe also states requirements: the hot water at the supply must be at least 2 °C warmer than the desired temperature, the minimum flow is 5 l/min, and above 5 bar of static pressure a pressure reducer is needed. A thermostatic mixer does not work with unpressurised (open-vented) water heaters, and with an instantaneous heater only if its power is at least 18 kW.
The brick walls stay, what changes is what is between them
The first standard blocks of Iļģuciems, series 303, were built with load-bearing brick walls, and later the district was built from five-storey large-panel sections. In both cases the bathroom walls are not usually moved, so the space for a shower comes in place of the bath.
LBN 200-21, clause 134: in flats, sanitary rooms are designed so that they can, if needed, be adapted for people with mobility impairments without affecting the load-bearing structures. Checked 16.11.2026.
A tray with no threshold and a low fitting height is one way to make a bathroom more convenient without changing the walls. Whether your drain allows it can be seen only on site.
When the choice has to become a job
Placing and connecting a new bath is from €60, removing the old bath is separate. Assembling and connecting a shower cabin is from €125 per set. For the job “shower instead of a bath” there is no single price; it is set on site after these factors:
- the old bath: it has to be taken out and carried away;
- what goes in its place: a shower cabin, a tray or a shower area with a drain;
- the drain: whether its height or position has to change to get a fall;
- the supply pipes: whether the water pipes and the mixer tap need moving;
- the floor height and how easy it is to reach the riser.
All are labour prices; materials are extra. The jobs are described on the pages bath replacement and shower cabin installation. On the call you talk through the job and the price.
Sources
- Ravak Rosa: top edge 610 mm ±5 mm; an acrylic bath is not built in rigidly, 2–3 mm gap with silicone; installed in a finished room, opening for trap access; fill first with cold water checked 16 November 2026
- Ravak Gigant Pro: cast-marble tray, fitting height 3 cm, can be built into the floor with no threshold checked 16 November 2026
- Kaldewei: drain with a double-lip seal; load before the joint; mortar does not touch the lower edge, sealing tape; cleaning with water and vinegar 1:1 checked 16 November 2026
- Grohe: safety stop 38 °C; hot water 2 °C warmer, min. 5 l/min, reducer above 5 bar; not with unpressurised heaters, instantaneous heater at least 18 kW checked 16 November 2026
- The first standard blocks of Iļģuciems, series 303, with load-bearing brick walls checked 16 November 2026
- Iļģuciems district from 1968 only with five-storey large-panel sections checked 16 November 2026
- LBN 200-21, clause 134: sanitary rooms adaptable for people with mobility impairments without affecting load-bearing structures checked 16 November 2026