In a flat in a series block, the water heater is a back-up for the summer day when the district heating network is tested and there is no hot water. In a private house it is the only source of hot water, so the size of the family and the time the tank needs to heat are what matter.
What a water heater shows before it fails completely
| What you notice | Why it happens | What to do | Price |
|---|---|---|---|
| The water takes longer and longer to heat | Deposits have built up on the heating element | Water heater descaling | from €75 |
| Hot water from the water heater flows weaker than cold water from the tap | The safety valve on the cold water inlet may be blocked | Check or replace the valve, see water heater repair | after inspection |
| The water heater stops heating by itself and the water turns lukewarm | The thermal cut-out against overheating has tripped | Finding the cause: the setting, limescale on the thermostat tube | after inspection |
| The anode light on the casing has come on | The signal anode shows the anode is worn | Anode check during descaling; a new anode and fitting it are charged separately | from €75 (descaling) |
| Only the hot water smells of hydrogen sulphide | The magnesium anode reacts with the sulphates in the water | See hot water smells | after inspection |
| Water seeps out of the casing itself | The tank has rusted through | Installing a new water heater | from €70 |
A flat’s water heater affects the neighbour below, a house’s water heater affects the whole house
In a series block the water heater connection starts after the flat’s valves. Under Article 3 of the Apartment Ownership Law, the utility lines as far as the common-property risers, together with the flat’s utility equipment, are separate property, so the water heater is usually the flat owner’s responsibility, unless the building’s documents say otherwise. Article 14 of the same law says a flat owner is liable for damage caused to others. If the water heater leaks, the water from your floor can reach the neighbour on the floor below.
In a private house the incoming supply pipe, the pipes and the water heater belong to one owner, and no neighbour suffers from a leak. But when the water heater does not heat, there is no hot water at any tap. In the middle of Kleisti, the “Spilves pļavas” private houses grew out of rebuilt allotments: in such a house the water heater runs every day, and its volume should be chosen by the family, not by the free space on the wall.
A water heater for the district heating test day
In summer, AS “Rīgas siltums” (Riga’s district heating company) tests the heating networks zone by zone. The test lasts one day: the evening before, the heat carrier is cooled to +45 degrees, and if no faults are found, hot water is restored that same evening. When the networks of the “Imanta” and “Zasulauks” heat plants are tested, there is also no hot water in the Iļģuciems and Grīva residential areas.
For a back-up water heater the heating time matters. The manufacturer (Gorenje) states that with a 2000 W heating element, water goes from 10 °C to 65 °C in 1 h 38 min in a 50-litre tank, 2 h 37 min in an 80-litre tank and 3 h 16 min in a 100-litre tank. If on test day you switch the water heater on only in the morning, the first shower comes after that time.
Water heater volume for a family in a house
In a private house the family decides the water heater volume: how many people shower one after another in the evening and whether someone fills a bath. You talk through the litres on the call; in the form, write how many people live in the house and whether it has a bath.
A bigger tank takes longer to heat. In Gorenje’s data, a 100-litre tank with the same 2000 W heating element takes twice as long as a 50-litre tank. For a family that washes in the evening, the time from cold to hot matters as much as the litres. For a flat’s back-up on test day, a smaller tank is enough, because it works a few days a year.
If a family fills a bath in the evening, a large share of the tank goes at once, and the next person has to wait for water. A bigger tank also needs a stronger wall and more space above the water heater for the anode replacement; the manufacturers' requirements are on the page water heater installation.
Three things not to do yourself with a water heater
- Do not leave a full water heater in a house where frost threatens or the power will be off for more than two months. The manufacturer (Atlantic) recommends emptying the water heater in such cases.
- Do not press the safety thermostat button while the water heater is live. In the manufacturer’s (Electrolux) description, resetting starts with disconnecting from the power and opening the service panel with a tool. If the thermostat cuts out repeatedly, the cause must be found.
- Do not hang a water heater over a floor with no waterproofing and no drain unless there is a tray under it. The manufacturer (Thermex) requires a protective tray under the water heater with an outlet to the drains in such places.
Installation from €70, descaling from €75, repair after inspection
Hanging a water heater and connecting it to the existing supply pipes with a safety valve is from €70 per unit. Limescale removal with an inspection of the heating element and the anode is from €75. Repair has no single price: it is set by the faulty part, if the water heater has to be drained and removed from the wall, whether spare parts exist for the model and whether the repair costs more than a new water heater. New pipes to the water heater’s position are from €10/m. Labour only; materials are extra.
Whether the trip is charged separately, the plumber tells you on the call before the work. After you submit the form, we contact you within 5 minutes, and on the call you talk through the job and the price.
Sources
- Hydraulic test of the heating networks in summer, zone by zone, one day, +45 degrees the evening before, hot water that same evening; building managers are informed checked 16 November 2026
- During the test of the Imanta and Zasulauks heat plant networks there is also no hot water in the Iļģuciems and Grīva residential areas checked 16 November 2026
- Apartment Ownership Law: Article 3 (separate property), Article 11 (work without agreement), Article 14 (liability for damage) checked 16 November 2026
- Heating time at 2000 W from 10 °C to 65 °C: 50 l 1 h 38 min, 80 l 2 h 37 min, 100 l 3 h 16 min; frost-protection position about 10 °C checked 16 November 2026
- A longer heating time points to deposits on the heating element; weaker hot water pressure can mean a blocked safety valve; the thermal cut-out trips above 95 °C; a protective tray under the water heater checked 16 November 2026
- Empty the water heater if frost threatens or the power is off for more than two months checked 16 November 2026
- Resetting the safety thermostat: disconnect from the power, open the service panel with a tool checked 16 November 2026
- Signal anode with a Service Anode indicator checked 16 November 2026
- Hydrogen sulphide smell only in the hot water: the magnesium anode reacts with sulphates checked 16 November 2026
- In the middle of Kleisti, the Spilves pļavas private-house complex grew out of rebuilt allotments checked 16 November 2026