Rīgas ūdens, analysing five years of failures, named Iļģuciems among the neighbourhoods with the most faults; in the networks of these neighbourhoods together, as much as 40 % of the length is on the critical list. Your part is the pipes from the riser or the meter chamber to the tap, and laying them costs from €10/m.
Signs in the pipes and the section to look in
| What you notice | Why it happens | What to do | Price |
|---|---|---|---|
| When you close a tap, the pipes knock or bang | Water hammer: the flow stops too suddenly | A water hammer arrester by the fixture that closes quickly | from €25/h |
| A joint under the sink or at the meter weeps drop by drop | A compression nut has loosened or the gasket is worn | Tighten it or replace the gasket | from €40 |
| The cold pipe in the duct sweats, and the water from it comes lukewarm | The hot or heating pipe beside it warms it | Separate the pipes or insulate them | from €25/h |
| Old steel rusts at the threads, and the stream is weak only in your flat | The pipe has grown over inside | Replace the section up to the taps | from €10/m |
| A wet lawn between the chamber and the house at a private house | A leak on the incoming supply pipe | Dig up and replace the faulty section | after inspection |
If brown water or weak pressure is throughout the building, it is usually the street network. The total length of Rīgas ūdens networks is 1,515 km with an average age of 46.5 years, and the sections in the worst condition are mostly those built in the Soviet period.
In a flat your pipes start at the riser, in a private house at the chamber wall
Under Article 3 of the Apartment Ownership Law, a flat owns the pipes up to the building’s common risers and also the sanitary equipment: toilet, shower, bath. Article 11 of the same law allows construction work in a flat without other owners' consent, as long as it does not affect common property and other flats. So the pipes after the flat’s valves can be replaced by closing only your own valves. The valves at the meters themselves are replaced when the building manager shuts off the riser.
In a private house the owner is responsible for the system from the ownership boundary to the building and inside it. Rīgas ūdens states that the meter chamber at the boundary is built by the property owner. In north-west Imanta, after 10.3 km of new water main was built, 185 households could connect: in each such house the incoming supply pipe from the chamber to the house is the owner’s pipe.
Pipes hum or bang when you close a tap
The manufacturer Caleffi explains that water hammer arises when the flow of water stops suddenly: a single-lever mixer tap closes, a washing machine’s solenoid valve closes, or a ball valve. In Caleffi’s example, in a 10 m long 1/2-inch pipe at a flow of 2 m/s, a sudden closing creates an overpressure of about 28.5 bar in a copper pipe and 18 bar in a PE-X pipe.
In plastic the overpressure is lower, but the manufacturer notes that it yields to the shock more easily, so taps are closed more slowly, and the arrester is placed as close as possible to the fixture that stops the flow. Banging is also made worse by high pressure. LBN 221-15 sets a limit: at the lowest water outlet the pressure must not exceed 0.6 MPa, that is 6 bar; in a tall building, for example a nine-storey series 602 block, the highest pressure is on the lower floors.
Pipes sweat or the cold water in the duct warms up
Sweating is condensation: the air of a warm room cools on a cold pipe. In the toilet’s boxed-in duct the cold pipe runs beside the hot pipe and the towel rail supply, and then it warms up. The manufacturer TECE warns that when warm pipes are laid beside cold drinking water pipes, the cold water must not warm above 25 °C. A new line is therefore run with a gap or with insulation.
Pipe installation and the pressure test
The manufacturer Rehau gives its PE-Xa pipes a maximum working pressure of 10 bar at 70 °C and a short-term emergency temperature of 95 °C, and a slide-on sleeve joint is made without soldering or an open flame. The TECE multilayer system meets class 2 of ISO 10508 and 10 bar, and it must never exceed 100 °C. Rīgas siltums states that a modernised heat substation gives hot water at 50–55 °C, well below these limits.
TECE requires a pressure test to DIN EN 806-4 while all the joints are still visible, and tightness is not judged only by the pressure gauge curve: the joints are also inspected by eye. The manufacturer Viega states that for its press fittings an unpressed joint visibly leaks in a water test at 0.1–0.65 MPa. So pipes are closed into the wall only after the test.
What not to do yourself with new pipes
- Do not tighten plastic fittings with a pipe wrench: TECE recommends a spanner so that the fitting is not deformed.
- Do not smear fittings with assembly foam, paint or solvents: TECE does not recommend this for its PPSU fittings.
- Do not wind too much flax fibre on a thread: TECE warns that it can damage the thread, and after tightening the thread ends must remain visible.
- Do not store pipes outdoors or on a balcony: UV radiation damages them over time.
What the pipe work price depends on
Laying a pipe along a wall or floor costs from €10/m; concealed laying in a wall costs more. One connection point, for example for a sink, is from €35, fixing a leak from €40, and small jobs at the hourly rate from €25/h. The price changes with the metres, the number of joints, whether the riser shut-off has to be waited for and whether a private house needs digging.
Example: 6 m of new pipe from the duct to the bath and the sink and two connection points come to 6 × €10/m plus 2 × €35, at least €130 in total. Whether the trip is charged separately, the plumber tells you on the call before the work. Labour only; materials are extra.
Sources
- Iļģuciems among the neighbourhoods with the most faults, up to 40 % of networks on the critical list; 1,515 km, average 46.5 years, Soviet networks the worst checked 16 November 2026
- Articles 3 and 11 of the Apartment Ownership Law checked 16 November 2026
- The meter chamber is built by the owner; the customer is responsible from the boundary to the building checked 16 November 2026
- North-west Imanta 10.3 km of water main, 185 households checked 16 November 2026
- Causes of water hammer, the 28.5 bar / 18 bar example, plastic, the arrester by the fixture checked 16 November 2026
- LBN 221-15 clause 35: at the lowest outlet no more than 0.6 MPa checked 16 November 2026
- Nine-storey series 602 blocks in Iļģuciems checked 16 November 2026
- TECEflex: ISO 10508 class 2, 10 bar, not above 100 °C; DIN EN 806-4 test and visual inspection; air test after 72 h; cold not above 25 °C; fittings, flax fibre, UV checked 16 November 2026
- Rehau RAUTITAN PE-Xa 10 bar at 70 °C, 95 °C short-term; slide-on sleeve without a flame checked 16 November 2026
- Viega SC-Contur: an unpressed joint leaks at 0.1–0.65 MPa checked 16 November 2026
- A modernised heat substation gives hot water at 50–55 degrees checked 16 November 2026
- PEX-a about 85 %, PEX-b 65–70 %, PEX-c 70–75 %; fixing a kink checked 16 November 2026