The protection switches off the heating, but the valve does not stop the water heater: it only releases excess pressure, and a blocked valve reduces the hot water flow. A repair is done when the tank is intact and the part is accessible; if the tank leaks, a new water heater is the better choice.
What a repair includes and does not include
Included:
- finding the faulty part;
- replacing one part: heating element, thermostat, anode or safety valve;
- draining and refilling the water heater, if the part cannot be reached otherwise.
Not included:
- the spare parts themselves;
- removing limescale from the tank, which is water heater descaling;
- repairing the electrical supply up to the water heater;
- a new water heater, if the tank leaks.
What stops the heating and what only weakens the flow
| What happens | Which part is at fault | Possible cause |
|---|---|---|
| The water becomes lukewarm, the water heater stops heating by itself | Overheating protection: the Thermex thermal cut-out switches off the heating element above 95 °C | The temperature is set too close to the limit, or limescale on the thermostat tube |
| A new water heater from the shop does not heat at all | The Stiebel Eltron high-temperature fuse | Stiebel Eltron: it trips if the unit has been below -15 °C in transport or in a warehouse |
| Hot water from the water heater runs weaker than cold | The safety valve on the cold water inlet (it does not stop the heating) | Thermex: the valve may be blocked |
| The water takes longer and longer to heat | None; the heating element heats more slowly | Thermex: deposits on the heating element |
Finding the fault from the outside in
- Power Check that power reaches the water heater and that the residual current device has not tripped. If the device switches off just when the water heater starts heating, the fault may be in the heating element or the wiring.
- Overheating protection Electrolux calls it a safety thermostat. In the manufacturer’s description it is reset only with the water heater disconnected from the power, the service panel opened with a tool and then closed.
- Working thermostat If the protection keeps switching off again and again, the working thermostat may be faulty. The manufacturer (Gorenje) states that in that case the water in the tank can reach even 130 °C, so such a water heater is not kept in use.
- Water side Compare the hot and cold water flow and inspect the safety valve on the inlet.
- Tank If water seeps from the body itself rather than from a joint, the tank cannot be repaired.
What to state in the form about the faulty water heater
- The make, model and capacity from the label.
- How many years the water heater has been running.
- What happens: lukewarm water, no heating at all, switching off, tripping the device, leaking.
- Whether the safety thermostat has already been reset and how many times.
- Whether the water heater is new and whether it was carried in a car in winter.
- A photo of the water heater, the valve and the place under it.
Water heater not heating: repair or a new one
If the tank is intact, replacing the heating element, thermostat or valve is usually less work than a new water heater. A repair does not pay off if the tank leaks through the body, if the model no longer has spare parts, or if the part and the labour together approach the price of a new water heater.
In the centre and south of Zolitūde, detached houses dominate. In such a house the water heater is the only source of hot water, and the decision on a repair or a new water heater has to be made within a day. A flat with the building’s hot water has time to compare both options.
The repair price depends on the part
There is no single price for a water heater repair. It depends on the faulty part, whether the tank must be emptied and the unit lifted off its mounting, whether the model has spare parts, and whether the repair costs more than a new water heater. A plumber’s call-out and inspection is from €40.
Example: the tank turns out to leak, and a new water heater is fitted in the old one’s place with 2 m of new pipe. Installation from €70 plus 2 × €10/m: at least €90 for labour, the water heater extra. Whether the trip is charged separately, the plumber tells you on the call before the work.
Sources
- The thermal cut-out switches off above 95 °C, causes of frequent tripping; weak hot water pressure = blocked safety valve; longer heating = deposits checked 16 November 2026
- The high-temperature fuse trips below -15 °C in transport or storage, reset with a button checked 16 November 2026
- Resetting the safety thermostat: disconnect from the power, open the panel with a tool, press the button, close checked 16 November 2026
- If the working thermostat fails, the water can reach 130 °C checked 16 November 2026